Move gates to 10 percent open as measured at the scale on the servomotors and check to see if the gate position needle indicates 10 percent. If the gate position needle does not indicate 10 percent, move the eccentric adjustment in the restoring shaft bell crank to position it correctly (photograph 3). Move it toward the restoring shaft if there is over travel and away from the restoring shaft if there is under travel (figure 7). Move the gates to 90 percent, as measured at the servomotor scale, and check the gate position indicator needle. It may...