  • The Standard TCXDVN 266:2002 is compiled by the Research Institute for Architecture and the panel for elaboration of “Codes and standards of construction accessibility for people with disabilities in Vietnam”, submitted by the Department of Science and Technology – Ministry of Construction, and approved, signed, issued by the said ministry for enforcement. The Standard TCXDVN 266 : 2002 is compiled with the cooperation and funding by President’s Committee on Employment of People with Disabilities (PCEPD) and Vietnam Assistance for the H andicapped (VNAH) ...

    doc35p alibabava40tencuop 21-09-2009 528 141   Download

  • Tham khảo tài liệu 'tcxdvn 266 1-0', kinh tế - quản lý, tiêu chuẩn - qui chuẩn phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả

    doc9p alibabava40tencuop 21-09-2009 118 21   Download

  • 5.5.3. Where in two sides of corridor there is wall edge, then the clearance width must be in accordance with regulation in clause 5.5.1. 5.5.4. Handrails in two sides of corridor must be at an elevation of 900mm. Rotating angle at deviation points is preferably arched wall face or right angled wall face. Where there is difference in elevation at the extremity of corridor and the end of corridor with floor surface or ground surface, it must be balustrade, shielding plate or shielding edge, and there is a need for installation of safety signpost. ...

    doc20p alibabava40tencuop 21-09-2009 127 41   Download

  • 5.14.6. When installing equipment in rooms, it is necessary to consider the height of reach by wheelchair users (calculated from floor or ground surface) and regulated as follows

    doc7p alibabava40tencuop 21-09-2009 113 25   Download

  • 5.14.16. On the walls around closet, safety handrail must be installed. Details of handrail must comply with stipulation in clause 5.12 of this guidance . Dimensions for installing handrail are as follows:

    doc8p alibabava40tencuop 21-09-2009 104 25   Download

  • 5.9.9. It is not advisable to arrange door sill or nosing in the interior side of door, in case the clearance space is less than 800 mm. Note: It is only permissible to arrange door sill and nosing in the interior side of door in case the clearance space exceeds 800 mm, and the door sill or nosing does not exceed 50 mm. 5.9.10. As for pulling door, sliding door, accordion door, the clearance space regarding each door type is shown in table 4 and table 5. a) Pulling door: Regulation on clearance space for wheelchair moving is indicated in fig 32....

    doc11p alibabava40tencuop 21-09-2009 119 21   Download

  • 5.7.5. Area of waiting space before entering the lift must not be less than 1,500 mm  1,500 mm. 5.7.6. The lift door is equipped with automatic closing, opening device. Time duration for door closing/ opening must be over 20 seconds. 5.7.7. The control switchboard in lift cabin is installed at an elevation not more than 1,200 mm and not less than 900 mm from the cabin floor to the center of highest control button. On control buttons there must be symbols or tactile signals and Braille raised dots for blind people. Symbols and Braille raised dots are shown...

    doc7p alibabava40tencuop 21-09-2009 83 19   Download