Xem 1-20 trên 110 kết quả Temperature control
  • Tham khảo sách 'siemens - simatic pid temperature control', kỹ thuật - công nghệ, tự động hoá phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả

    pdf102p trinh02 23-01-2013 37 14   Download

  • This manual supports you when you work with the temperature controller block from the Standard Library PID Control. It will familiarize you with the functions of the controller blocks and, in particular, with tuning the controller and working with the user interface in which you set the parameters for the blocks. There is an online help system for both the blocks and the user interface that supports you when setting the parameters of the blocks. This manual is intended for qualified personnel involved in programming, configuration, commissioning, and servicing of programmable controllers.

    pdf42p trinh02 23-01-2013 53 16   Download

  • For simple applications, switching devices such as contactors or solid-state relays can be used to control electrical power. The electrical power in a process can be regulated by varying the ON and OFF times of these devices. But in many processes this provision of energy in large blocks will cause significant variations in the process output. As an example, it would not be possible to control lighting levels simply by using such two-state on/off switching elements. Neither could good temperature controllers be implemented in this way...

    pdf44p beobobeo 01-08-2012 34 8   Download

  • Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành hóa học dành cho các bạn yêu hóa học tham khảo đề tài: Copper Selenide Nanosnakes: Bovine Serum Albumin-Assisted Room Temperature Controllable Synthesis and Characterization

    pdf8p sting07 17-02-2012 24 2   Download

  • This is documented on its ENC inverter, inverter EDS currently uses quite a lot because of its low cost and ease of installation are full of style and function that controls the inverter reputation has, howeverreliability is not very high.

    pdf149p hungcoi312 23-06-2010 461 346   Download

  • Process plants consist of hundreds, or even thousands, of control loops all networked together to produce a product to be offered for sale. Each of these control loops is designed to keep some important process variable such as pressure, flow, level, temperature, etc. within a required operating range to ensure the quality of the end product. Each of these loops receives and internally creates disturbances that detrimentally affect the process variable, and interaction from other loops in the network provides disturbances that influence the process variable....

    pdf297p trinhvang 18-01-2013 50 28   Download

  • Automatic process control is concerned with maintaining process variables, temperatures, pressures, flows, compositions, and the like, at a desired operating value. As we shall see in the ensuing pages, processes are dynamic in nature. Changes are always occurring, and if actions are not taken, the important process variables— those related to safety, product quality, and production rates—will not achieve design conditions.

    pdf227p nhatkyvodanh 11-08-2012 53 19   Download

  • This subcourse is designed to provide instruction on the concept and operation of the basic components of the hydraulic system. It also describes the various components of a typical hydraulic system, their construction and functions, and their relationship to each other. When the term hydraulics is applied to aircraft, it means a method of transmitting power from one location to another through the use of a confined fluid.

    pdf67p chipmoon 19-07-2012 51 14   Download

  • Just as human operators must be protected from extreme environments, so must the electronics that operate and control a functional system. When the environment proves too warm, the electronics must be insulated, refrigerated, or simply moved to cooler locations. This last option is sometimes very difficult, or impossible, and the perceived fragility of electronics must then be reconsidered. Vacuum-tube technology provides a historical example of this process.

    pdf136p thix1minh 16-10-2012 21 4   Download

  • This new science seeks to emphasize the immediate duty of man to better his conditions by availing himself of knowledge already at hand. As far as in him lies he must make application of this knowledge to secure his greatest efficiency under conditions which he can create or under such existing conditions as he may not be able wholly to control, but such as he may modify. The knowledge of the causes of disease tends only to depress the average citizen rather than to arouse him to combat it. Hope of success will urge him forward, and it is the duty of lovers of mankind...

    pdf65p hotmoingay9 02-02-2013 16 2   Download

  • Trong hệ thống điều khiển tự động EATC (Electronic Automatic Temperature Control) có trang bị bộ vi xử lý để giúp hệ thống duy trì được nhiệt độ mát lạnh định sẵn một cách ổn định. Đồng thời có thể điều khiển được nhiệt độ ở phía ghế tài xế và khu vực ghế hành khách một cách độc lập.

    pdf4p haidaioto 08-10-2013 432 170   Download

  • Solar energy, light and heat radiation from the Sun, has been exploited by humans since ancient times using a variety of technology development than ever before. Solar radiation along with secondary resources of energy like wind and solar energy, water power and biomass, make the most of renewable energy available on earth. Only a tiny fraction of the available solar energy is used.

    ppt202p minhhai20789 26-04-2011 187 110   Download

  • This subcourse is designed to provide instruction on the concept and operation of the basic components of the hydraulic system. It also describes the various components of a typical hydraulic system, their construction and functions, and their relationship to each other.

    pdf67p protable 26-02-2010 194 82   Download

  • Long-time protection: The long-time protection function protects cables (phases and neutral) against overloads. This function is based on true rms measurements. Thermal memory: The thermal memory continuously accounts for the amount of heat in the cables, both before and after tripping, whatever the value of the current (presence of an overload or not). The thermal memory optimises the long-time protection function of the circuit breaker by taking into account the temperature rise in the cables. The thermal memory assumes a cable cooling time of approximately 15 minutes....

    pdf31p nmtinh 10-11-2010 196 62   Download

  • This text is aimed at technicians, hobbyists, and students and provides complete circuit diagrams and building instructions for a wide range of creative sleuthing applications. The designs are fully tested and proven effective in real-world alarm, sensor, and security equipment. Among the circuits highlighted are a multi-purpose high-gain amplifier, temperature and pressure sensors, vibration and pyroelectric sensors, smoke and toxic gas detectors, tachometer/speed gauges, a remote video and control system, door and window alarms, motion and impact detectors and tone signalling sensors.

    pdf296p ndkhuong177 20-06-2012 149 59   Download

  • Temperature measurement and control are vital in many industrial processes. Accurate control of the temperature is essential in nearly all chemical processes. In some applications, an accuracy of around 5-10~ may be acceptable. There are also some industrial applications which require better than 4-1 ~ accuracy.

    pdf233p cusonson 21-01-2010 120 54   Download

  • The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles.

    pdf0p ledung 13-03-2009 158 52   Download

  • The increasing global demand for processed foods has led to a greater prominence of the food industry, its specific needs and processing challenges. Consequently, in recent times the role of the engineer in the food industry has gained considerable prominence. In contrast to other more traditional processing industries, the raw materials or ingredients that are used tend to be of greater complexity in nature.

    pdf0p namde01 10-04-2013 41 21   Download

  • The temperature sensor for an electronic controller may be a length of wire or a thin metallic film (called a resistance temperature device or RTD) or a thermistor. Both types of resistance elements change electrical resistance as temperature changes. The wire increases resistance as its temperature increases. The thermistor is a semiconductor that decreases in resistance as the temperature increases. Because electronic sensors use extremely low mass, they respond to temperature changes more rapidly than bimetal or sealed-fluid sensors. The resistance change is detected by a bridge circuit.

    pdf10p liemthanh 15-12-2009 68 12   Download

  • Sedation is the important factor in comfort of brain trauma patients. Insuffient sedation causes hypertension, tachycardia, hypoxia, hypercapnia and uncomfortable with ventilator. On the other hand excess sedation causes hypotansion, bradycardia, coma, respiratory depresion, ileus, renal insufficiency, veinous stasis and immunosupression. For the patients in the critical care unit firstly nonpharmacological method should be experinced for sedation. The patients should be frequently oriented.

    pdf274p wqwqwqwqwq 21-07-2012 52 8   Download