This study investigated effect of initial pH and current intensity on both the amount of hydrogen peroxide production and the Glyphosate mineralization performance. The results indicated that at pH 3, the quantity of H2O2 production on cathode was highest (~0.15 mg/L), and the Glyphosate mineralization performance was optimum, approximately 60% at an electrolysis time of 50 min.