Motor Drive Schemes177
discharge. Later, when the current decays to I~ a switch closes and
the inductance charges until the next clock pulse appears. Once again
the switching frequency is fixed by the clock frequency.
Important aspects
of
this PWM scheme include:
• Current control is not as precise here, since there is no
fixed
tolerance
band that bounds the current.
• The frequency at which switches change state is a fixed design pa-
rameter.
• Acoustic and electromagnetic noise are relatively easy to filter be-
cause the switching frequency is fixed.
• This PWM method has ripple instability that produces subharmonic
ripple components for duty cycleszyxwvutsrqponmlkjihgfedcbaZXWVUTSRQPONMLKJIHGFEDCBA below 50 percent (Kassakian,
Schlecht, and Verghese, 1991; Anunciada and Silva, 1991). While
this instability does not lead to any destructive operating mode, it
is a chaotic behavior that reduces performance. The predominant
current ripple occurs at one-half the switching frequency.
Dual current-mode PWM
This PWM method was developed by Anunciada and Silva (1991) to
eliminate the ripple instability present in the previous two methods.
Their scheme combines the clocked turn-ON and clocked turn-OFF
methods in a clever way. For duty cycles below 50 percent, the method
implements stable clocked turn-ON PWM, whereas for duty cycles

178 Chapter Seven
above 50 percent, the method implements stable clocked turn-OFF
PWM.
As illustrated in Fig. 7.18, this method has two clock signals, where
the turn-OFF clock is delayed one-half period with respect to the turn-
ON clock. Operation is determined by logic that initiates inductor
charging when the turn-ON clock pulse appears or the current reaches
I~, and initiates inductor discharge when the turn-OFF clock appears
or the current reaches / + . As shown in the figure, the method smoothly
moves from one mode to the other. This scheme has all the attributes
of
the two previous PWM schemes, except for the ripple instability.
Furthermore, this scheme reduces to hysteresis PWM
if
the clock fre-
quency is low compared with the rate at which the inductance charges
and discharges.
Triangle PWM
Triangle PWM is a popular voltage PWM scheme that is commonly
used to produce a sinusoidal PWM voltage. When used in this way, it
is called sinusoidal PWM (Kassakian, Schlecht, and Verghese, 1991).

Motor Drive Schemes 179
Processed
Application of this scheme to current control is accomplished by letting
the PWM input be a function of the difference between the desired
current and the actual current. As shown in Fig. 7.19, both the turn-
ON and turn-OFF
of
the switch are determined by the intersections
of
the triangle waveform and the processed current error. As the pro-
cessed current error increases, so does the switch duty cycle. Typically,
the processed current error is equal to a linear combination of the
current error and the integral
of
the current error, i.e., PI control is
used. As a result, as the steady-state error goes to zero, the switch duty
cycle will go to the correct value to maintain it there. Though Fig. 7.19
shows a unipolar triangle waveform and error signal, both signals can
also be bipolar, in which case zero current error produces a 50 percent
duty cycle PWM signal (Murphy and Turnbull, 1988).
Summary
The PWM methods discussed above represent the most common meth-
ods implemented in practice. Each method has its own strengths and
weaknesses; no one PWM scheme is the best choice for every motor
drive. Implementation details for the above PWM methods were not
presented so that attention would
focus
on fundamental switching con-
cepts. For reference, conceptual logic diagrams for each method are
shown in Fig. 7.20. These diagrams apply for positive currents only.
When the reference current is bipolar, more complex logic diagrams
are required.

Motor Drive Schemes
switching
frequency,
the smaller the current error will be. On the other
hand, the higher the switching frequency, the greater the switching
loss incurred by the switches. Furthermore, PWM schemes are only as
accurate as the current sensors used. Sensor type, placement, shielding,
and signal processing are all critical to accurate operation
of
a current
control PWM method.

Appendix
A
List of Symbols
AzyxwvutsrqponmlkjihgfedcbaZYXWVUTSRQPONMLKJIHGFEDCBA Area (m2)
B Magnetic
flux
density (T)
Ba Armature reaction
flux
den-
sity (T)
Bg Air gap
flux
density (T)
Br Magnet remanence (T)
CA Flux concentration factor
D Diameter (m)
E Voltage,
emf (V)
Eb Back
emf (V)
Emax Maximum back
emf (V)
F Magnetomotive force,
mmf (A)
Force (N)
H Magnetic field intensity
(A/m)
Hc Magnet coercivity (A/m)
I Current (A)
Is Total slot current (A)
Js Slot current density (A/m2)
Jmax Maximum current density
(A/m2)
L Length (m)
Inductance (H)
Le End turn inductance (H)
Lg Air gap inductance (H)
Ls Slot leakage inductance (H)
M Mutual inductance (H)
N Number
of
turns
Nm Number
of
magnet poles
Np Number
of pole
pairs
Nph Number
of
phases
Ns Number
of
slots
N Number
of
slots per magnet
pole
Nsp Number
of
slots per phase
N
*
spp
Number
of
slots per pole per
phase
p Permeance (H)
Average power (W)
Pc Permeance
coefficient
Pel Core loss (W)
Pe Eddy current power loss (W)
Pg Air gap permeance (H)
Ph Hysteresis power loss (W)
Php Power (hp)
Pr Resistive, ohmic, or I2R loss
(W)
R Resistance (fl)
Reluctance (H_1)
Radius (m)
S Motor speed (rpm)
183