![](images/graphics/blank.gif)
Locking plate fixation
-
To describe some clinical characteristics of adult patients with closed proximal humerus fracture (PHF), treated by osteosynthesis method with locking plate. Subjects and methods: Adult patients who were closed PHF treated by open reduction and locking plate fixation at Military hospital 175. Report of a retrospective study conducted on 42 clinical cases.
5p
vicarlos
16-05-2024
3
1
Download
-
To evaluate the functional outcomes of surgical treatment for proximal femoral fractures. Subjects and methods: This prospective study included 89 cases with proximal fractures of the femur in whom locking plate fixation, or bipolar head arthroplasty was performed between April 2020 and January 2021 at the Orthopedic and Trauma Center, Military Hospital 103.
9p
viharry
15-12-2022
2
2
Download
-
The aim of this study was to compare two types of fixation implants, locking compression system and locking system, evaluating radiographically the progression of osteoarthritis of the stifle joint in dogs with complete cranial cruciate ligament deficiency treated surgically with tibial plateau levelling osteotomy.
7p
vidarwin
23-02-2022
12
1
Download
-
Treatment of medial clavicle fractures is still controversially discussed in the community of upper extremity surgeons. An increasing number of symptomatic non-unions following conservative treatment of displaced fractures led to the development of various surgical approaches.
7p
vimackenziebezos
30-11-2021
4
1
Download
-
This study was to compare clinical and radiographic outcomes with three different implants and evaluate the effectiveness of minimally invasive plate osteosynthesis (MIPO) technique for the distal fibular fractures.
9p
viannito2711
20-04-2021
10
1
Download
-
Use of screw locking elements improves radiological and biomechanical results of femoral osteotomies
Dynamic compression plate (DCP) constructs provide inadequate fixation in cases of poor bone quality and early weight-bearing. Screw locking elements (SLE) are flat locking nuts placed at the end of the screw to prevent screw stripping from the bone, improving fixation stability.
8p
viannito2711
20-04-2021
13
2
Download
-
The use of minimally invasive plate osteosynthesis (MIPO) via anterolateral deltoid splitting has good outcomes in the management of proximal humerus fractures. While using this approach has several advantages, including minimal soft tissue disruption, preservation of natural biology and minimal blood loss, there is an increased risk for axillary nerve damage.
7p
viannito2711
20-04-2021
10
2
Download
-
This study aimed to present functional results and patient’s health related quality of life (HRQOL) data ten years after volar locked plate fixation (VPF) of unstable intra-articular distal radial fractures (DRF).
7p
viannito2711
20-04-2021
8
1
Download
-
Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP).
7p
viannito2711
20-04-2021
8
2
Download
-
Fractures of the distal radius are common and account for an estimated 17% of all fractures diagnosed. Two-thirds of these fractures are displaced and require reduction. Although distal radius fractures, especially extra-articular fractures, are considered to be relatively harmless, inadequate treatment may result in impaired function of the wrist.
7p
viannito2711
20-04-2021
13
2
Download
-
Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals.
7p
viannito2711
20-04-2021
10
1
Download
-
Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weightbearing constructs are still lacking.
8p
vianttinic2711
20-04-2021
10
1
Download
-
The neurovascular bundle containing the deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy (OWHTO), particularly due to drilling for bicortical fixation at distal screw holes.
10p
vianttinic2711
20-04-2021
14
2
Download
-
In the modern western world appraisal of economical points such as treatment and disability after trauma present a financial burden. In this context open reduction internal fixation techniques allowing for early full weight bearing might not only improve the clinical outcome but also shorten the period of disability in working life.
10p
vianttinic2711
20-04-2021
12
2
Download
-
The purpose of our study was to evaluate the effectiveness of this method in treating femoral shaft nonunion after open reduction and internal fixation with locked intramedullary nail fixation.
6p
trinhthamhodang1218
03-03-2021
14
2
Download
-
Fractures of the clavicle present very common injuries with a peak of incidence in young active patients. Recently published randomized clinical trials demonstrated an improved functional outcome and a lower rate of nonunions in comparison to non-operative treatment.
7p
vioregon2711
22-02-2021
6
1
Download
-
The ideal method for the surgical treatment of proximal humeral fractures has not yet been found. We therefore conducted a retrospective matched-pair analysis and compared osteosynthesis with open reduction and internal fixation and that with an angular stable plate with minimally invasive, closed reduction, percutaneous fixation with the Humerusblock.
9p
vioregon2711
22-02-2021
8
1
Download
-
Proximal humerus fractures are the third most common fracture in the elderly population and are expected to increase due to the aging population. Surgical fixation with locking plate technology has increased over the last decade despite a lack of proven superiority in the literature.
10p
vitennessee2711
01-02-2021
10
1
Download
-
Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment.
6p
vitennessee2711
02-02-2021
10
2
Download
-
Proximal humeral fractures treated with locking plate can fail due to varus collapse, especially in osteoporotic bone with medial cortex comminution. The use of an intramedullary strut together with locking plate fixation may strengthen fixation and provide additional medial support to prevent the varus malalignment.
7p
vitennessee2711
02-02-2021
6
1
Download
CHỦ ĐỀ BẠN MUỐN TÌM
![](images/graphics/blank.gif)