![](images/graphics/blank.gif)
Graphite electrode
-
In the present study, CoFe2 O4 /reduced graphene oxide (CoFe2 O4 /rGO) has been synthesized. The morphology and structure of nanocomposites CoFe2 O4 /rGO were characterized by X-ray diffraction (XRD), Energy Dispersive X-Ray spectrometer (EDX), scanning electron microscopy (SEM), and Fourier Transform infrared spectroscopy (FTIR).
8p
vigojek
02-02-2024
4
1
Download
-
In this study, saline wastewater is treated by electrochemical oxidation with two types of Graphite and Ti/RuO2 electrodes. Experiments were conducted to investigate the effect of reaction conditions such as salt concentration, current density, electrolysis time and pH on COD removal efficiency and electrode activity.
8p
vishekhar
25-10-2023
9
3
Download
-
A selective, simple and sensitive electrochemical sensor has been developed using pencil leads (pencil graphite electrode, PGE) for the investigation of chlorpromazine (CPZ). The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed to study the anodic behaviour of CPZ.
6p
viberbers
09-08-2023
6
3
Download
-
In this study, a graphite electrode (GrE) modified with polyglutamic acid was used as a sensor for the determination of chloramphenicol (CAP) - a phenicol antibiotic - in water environment using adsorptive stripping linear sweep voltammetry.
13p
viannee
02-08-2023
7
3
Download
-
In this study, the biosynthesis of Au and Ag nanoparticles (AuNp and AgNp) with a green chemistry approach was performed by using bioextracts of various fruits and vegetables (Lycopersicon esculentum (LE), Cucumis sativus (CS), Malus domestica (MD), Cucurbita pepo (CP), Apiumgraveolens var. rapaceum (AVR), Prunus cerasifera (PC), Oleraceae var. botrytis (OVB)).
16p
lyhuyenthu
31-01-2023
4
2
Download
-
Disposable sensors based on a pencil graphite electrode were described for detection of alkyl phenols. The performances of the disposable bare pencil graphite electrode (PGE) and PGE modified with carbon nanotubes, regarding the cyclic and differential pulse voltammetric determination of 4-nonylphenol, 4-octylphenol, and 4-tert-octylphenol, were compared. Some experimental variables of the electrode surface pretreatment and measurement parameters were optimized. Using a phosphate buffer solution (pH 7.
10p
langthannam
29-12-2021
13
0
Download
-
Two meso-dichlorophenyl substituted metallocorroles were synthesized and characterized as to their electrochemical and spectroelectrochemical properties in dichloromethane, benzonitrile, and pyridine containing 0.1 M tetra-n-butylammonium perchlorate (TBAP) as supporting electrolyte. The examined compounds are represented as (Cl2Ph)3 CorFeIVCl and (Cl2Ph)3 CorMnIVCl where (Cl2Ph)3 Cor is the trianion of 5,10,15-tri(2,4-dichlorophenyl)corrole.
12p
langthannam
29-12-2021
5
0
Download
-
Single-walled carbon nanotube (CNT) and chitosan composite (chitosan*CNT) based sensors were developed as DNA biosensors, and then they were applied for electrochemical investigation of the interaction between the anticancer drug mitomycin C (MC) and DNA. The oxidation signals of MC and guanine were monitored before and after the interaction process by differential pulse voltammetry (DPV). The DPV results were in good agreement with those of electrochemical impedance spectroscopy (EIS).
12p
langthannam
29-12-2021
9
0
Download
-
The present paper describes the use of a disposable pencil graphite electrode (PGE) for the voltammetric determination of famotidine. Cyclic voltammetric studies using different supporting electrolytes emphasized an irreversible oxidation of famotidine on the PGE. The electrode process is diffusion-controlled and pH-dependent. Differential pulse voltammetry (DPV) in phosphate buffer solution of pH 6.81 was employed for famotidine’s quantitative determination.
11p
langthannam
29-12-2021
7
0
Download
-
This paper presents a simple, rapid, and accurate voltammetric method for determination of boron in water and steel samples using a disposable pencil graphite electrode. The oxidation of Tiron in the boron–Tiron complex in phosphate buffer at pH 7.5 was measured as a response. Type and concentration of supporting electrolyte, pH, ionic strength, Tiron concentration, scan rate, step amplitude, pulse amplitude, and pencil grade were investigated as the parameters affecting the peak current.
10p
langthannam
29-12-2021
7
0
Download
-
Four different Mannich base derivatives containing an aromatic/heteroaromatic propanone structure (C1 (3-(dimethylamino)-1-(thiophen-2-yl)propan-1-one hydrochloride); C2 (3-morpholino-1-(pyridin-3-yl)propan-1-one hydrochloride); C3 (3-(dimethylamino)-1-(1H -indol-3-yl)propan-1-one hydrochloride), C4 (3-(piperidin-1-yl)-1-(pyren-1- yl)propan-1-one hydrochloride)) were earlier synthesized and characterized with 1 H NMR, 13 C NMR, MS, and elemental analysis.
8p
langthannam
29-12-2021
6
0
Download
-
The present work examıned the use of biochar derived from tea waste as a novel electrode material. For the fabrication of the biochar electrode, suitable amounts of biochar and graphite were mixed with mineral oil for the first time. The electrochemical performance of the biochar-modified carbon paste electrode (BCPE) was measured by various cyclic voltammetric reactions for several redox systems. The factors affecting the electrode kinetics of BCPE surfaces were examined and optimized. The BCPE was applied as transducer in a glucose biosensor.
11p
langthannam
29-12-2021
6
0
Download
-
The present article describes a method of determination of low antimony concentrations using a graphite furnace AAS technique after electrochemical preconcentration. A 2-electrode flow-through cell was developed with a working electrode made of gold-coated porous carbon and an accessory Pt electrode. This cell worked in online coupling with the graphite furnace atomizer. Accumulation occurred from the 6 M hydrochloric acid solution and 2M nitric acid was used to dissolve and transport antimony into the sampling loop. The sampling loop was placed on a 6-way valve.
8p
tudichquannguyet
29-11-2021
6
1
Download
-
The results showed that the electrolysis process was not affected by the electrode’s distance or area. The most efficient treatment for all three metals was achieved at a current value of 31.58 mA, which corresponds to a current density of 1.974 mA/cm2 under a voltage of 3 V, 8-h electrolysis time, wastewater pH
7p
princessmononoke
29-11-2021
10
1
Download
-
A pencil graphite electrode (PGE) was used for the simultaneous detection of ascorbic acid (AA), norepinephrine (NE), and uric acid (UA) by differential pulse voltammetry and cyclic voltammetry. The anodic peaks of AA, NE, and UA in their mixture can be well separated in 0.1 M Britton–Robinson buffer solution at pH 4.0. The effects of various experimental parameters such as pH, scan rate, and voltammetric parameters on the voltammetric response of these compounds were investigated.
12p
tudichquannguyet
29-11-2021
13
1
Download
-
A highly sensitive and simple method based on an ionic liquid/ex situ bismuth film-modified single-use pencil graphite electrode (IL/Bi/PGE) was offered for the electrochemical detection of cefixime (CEF) for the first time. The synergistic effects of the ionic liquid and bismuth film combination as the surface modifier remarkably improved the electrochemical response of the modified sensor. Anodic oxidation of CEF was observed at 0.9 V vs. Ag/AgCl/3 M KCl as one well-defined irreversible oxidation peak.
14p
tudichquannguyet
29-11-2021
9
2
Download
-
Voltammetric behaviors of six nitro-substituted benzamides, which are potential prodrug candidates for nitroreductase-based cancer therapy, were investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrochemical behavior of aromatic nitro (ArNO2) compounds by CV indicates that compounds involve various reduction/oxidation steps including the formation of aromatic nitro radical, nitroso, hydroxylamine, and amine groups.
19p
tudichquannguyet
29-11-2021
4
1
Download
-
In this paper, we report a simple, low-cost, and environmentally friendly electrochemical method to obtain a novel copolymer consisting of 1-pyrenyl-2,5-di(2-thienyl)pyrrole and pyrrole on a pencil graphite electrode (PGE). Poly(1-pyrenyl)-2,5-di(2-thienyl)pyrrole-co-pyrrole) that is P(PyrPy-co-Py) film was prepared by one-step potentiostatic codeposition in an ethanol solution containing PyrPy and Py monomers for supercapacitor applications. The electrodeposition of homopolymer and copolymer modified electrodes was carried out on the surface of the PGE via chronocoulometry.
16p
tudichquannguyet
29-11-2021
7
1
Download
-
The present paper describes the voltammetric analysis of dipyridamole (DIP) at a cheap, disposable pencil graphite electrode (PGE). The working conditions were optimized with regard to the electrode material and the supporting electrolyte. Cyclic voltammetric investigations emphasized that DIP is irreversibly oxidized at the PGE. The electrode process is pH-dependent and controlled by both diffusion and adsorption. For DIP quantitative determination a differential pulse voltammetric (DPV) method in phosphate buffer solution pH 7.00 was developed.
14p
tudichquannguyet
29-11-2021
8
1
Download
-
Glucose oxidase was covalently immobilized to a porous electrode, which was developed by using ferrocene functionalized polyethyleneimine, multiwall carbon nanotubes, and carbon cloth for biofuel cell applications in our recent studies. The kinetics parameters (i.e. kM, Vmax) and other parameters required for the modeling study were determined experimentally. Fuel cell flow channel geometry was analyzed by a computational fluid dynamics modeling approach. Substrate flow rate and mass transfer for each proposed channel type were considered in the simulations.
17p
tudichquannguyet
29-11-2021
5
1
Download
CHỦ ĐỀ BẠN MUỐN TÌM
![](images/graphics/blank.gif)