Supraglottic airway devices
-
The I-gel is a second-generation supraglottic airway device that is built with a noninflatable elliptical gel material cuff and has a wide semirigid stem. The I-gel supralaryngeal seal has shown promising efficacy for both spontaneous and controlled ventilation under general anesthesia.
3p vigamora 23-05-2023 4 2 Download
-
A new supraglottic device, the LMA-Supreme™, has recently become available for clinical use. Information on anaesthetic and co-adjuvant requirements for insertion of the LMA-Supreme™ is limited. The present study aimed to evaluate the optimal effect-site concentration of propofol in 50 % (EC50) of adults necessary for successful insertion of the LMA-Supreme™ and to examine remifentanil’s effect on propofol requirements.
10p viisaacnewton 25-04-2022 9 1 Download
-
The Streamlined Liner of the Pharynx Airway (SLIPA), a type of supraglottic airway, has a non-inflatable cuff that softens at body temperature to fit the laryngeal structure. We investigated whether pre-warming of SLIPA to body temperature may improve insertion parameters.
7p viisaacnewton 25-04-2022 7 1 Download
-
The third-generation streamlined liner of the pharynx airway (SLIPA-3G) is a new-generation supraglottic airway device (SAD) that is non-cuffed and disposable, with a sealing pressure that varies dynamically with the airway pressure. This study compared the SLIPA-3G with the laryngeal mask airway supreme (LMAS) in patients undergoing laparoscopic cholecystectomy.
6p viisaacnewton 26-04-2022 10 1 Download
-
The conventional sequence when using supraglottic airway devices is insertion, cuff inflation and fixation. Our hypothesis was that a tighter fit of the cuff and tip could be achieved with a consequently lower incidence of air leak, better separation of gastrointestinal and respiratory tracts and less airway morbidity if the device were first affixed and the cuff then inflated.
7p viisaacnewton 26-04-2022 10 1 Download
-
The LMA Protector™ is the latest CE marked single use supraglottic airway device. This airway device provides access and functional separation of the respiratory and digestive tracts. There are two ports (male, female ports) to provide suction in the laryngeal region and insertion of the gastric tube.
5p viottohahn 30-03-2022 11 1 Download
-
The use of supraglottic airway devices (SADs) in surgeries with laparoscopic pneumoperitoneum and Trendelenburg (LPT) positioning is controversial due to concerns about insufficient pulmonary ventilation and aspiration.
7p viottohahn 30-03-2022 8 1 Download
-
Laryngeal mask UNIQUE® (LMAU) is supraglottic airway device with good clinical performance and low failure rate. Little is known about the ideal position of the LMAU on the magnetic resonance imaging (MRI) and whether radiological malposition can be associated with clinical performance (audible leak) in children.
6p vampires36 30-12-2021 7 0 Download
-
Laryngeal mask airway is a supraglottic airway device which has led to a fundamental change in the management of modern general anesthesia. In the present study; we evaluated the laryngeal mask airway insertion conditions and hemodynamic changes comparing ketamine-propofol mixture (ketofol) with propofol.
8p vampires36 30-12-2021 9 0 Download
-
Dental injury is a common perioperative complication, but there are no country specific data available, especially with the use of supraglottic airway devices (SAD). The aims of our study are to report the incidence, risk factors, and local practices in the management of perioperative dental injuries in Singapore.
5p vampires36 30-12-2021 10 1 Download
-
Supraglottic airway devices (SGA) are commonly used in pediatric anesthesia and serve as primary or back-up devices for difficult airway management. Most SGA are marketed without proper clinical evaluation. The purpose of this study was to evaluate the performance of the pediatric LMA Supreme™, Air-Q® and Ambu® Aura-i™.
8p vampires36 30-12-2021 10 0 Download
-
Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation.
9p vampires36 30-12-2021 14 0 Download
-
The application of bedside ultrasound to evaluate gastric content and volume can assist in determining aspiration risk. Applying positive pressure ventilation via supraglottic airway devices (SAD) can result in a degree of gastric insufflation. This study assessed and compared the antral cross-sectional area (CSA) in patients undergoing laparoscopic gynecological surgery when managed with different SAD.
7p vizhangzhidong 29-12-2021 7 0 Download
-
The 4th National Audit Project of The Royal College of Anaesthetists and The Difficult Airway Society (NAP4) reported a higher incidence of supraglottic airway device (SAD) related pulmonary aspiration in obese patients especially with the first-generation SADs.
8p vizhangzhidong 29-12-2021 9 0 Download
-
Sevoflurane induction provides acceptable conditions for laryngeal mask insertion, and remifentanil significantly decreases the minimum alveolar concentration of sevoflurane required for that insertion. The study aimed to evaluate the optimal end-tidal (ET) sevoflurane concentration for successful insertion of PLMA versus SLMA in patients receiving a remifentanil infusion without a neuromuscular blocking agent.
9p vizhangzhidong 29-12-2021 9 0 Download
-
The LMA Gastro™ is a new supraglottic airway device, developed specifically for upper gastrointestinal endoscopy and interventions. The aim of this study was to evaluate the feasibility of LMA Gastro™ in patients with ASA physical status ≥3 undergoing advanced endoscopic procedures.
7p vizhangzhidong 29-12-2021 11 0 Download
-
In clinical practice, the laryngeal mask airway is an easy-to-use supraglottic airway device. However, the cis-atracurium dosage for laryngeal mask insertion has not been standardised. We aimed to determine the optimal dose of cis-atracurium using a sequential method for successful laryngeal mask insertion.
9p vizhangzhidong 29-12-2021 7 0 Download
-
After prehospital insertion of i-gel, a popular supraglottic airway (SGA), fiberoptic-guided intubation through i-gel is often required to switch the i-gel to a definitive airway for anticipated difficult airway. The Aintree intubation catheter (AIC) was developed for this purpose yet it requires many procedural steps during which maintenance of adequate ventilation is difficult.
7p vizhangzhidong 29-12-2021 6 0 Download
-
The peak inspiratory pressure (PIP) is crucial in mechanical ventilation with supraglottic airway device (SAD). Pressure-controlled ventilation volume-guaranteed (PCV-VG), delivering a preset tidal volume with the lowest required airway pressure, is being increasingly used during general anesthesia.
10p vidietmarhopp 29-12-2021 9 1 Download
-
Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học quốc tế cung cấp cho các bạn kiến thức về ngành y đề tài: Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin.
23p toshiba18 31-10-2011 48 2 Download