![](images/graphics/blank.gif)
Implant stability
-
While commonly utilized to fx tissue and muscles to megaprostheses to restore function and stability after tumor surgery, an attachment tube was used as a synthetic reconstruction of the knee joint’s extension mechanism after nonunion of Felix IV C fracture. Fixation of the tibial fragment, and therefore its osteointegration, is complicated after total knee arthroplasty, causing tibial tubercle dislocation.
5p
vilazada
31-01-2024
2
2
Download
-
Poor osseointegration is the key reason for implant failure after arthroplasty,whether under osteoporotic or normal bone conditions. To date, osseointegration remains a major challenge. Recent studies have shown that deferoxamine (DFO) can accelerate osteogenesis by activating the hypoxia signaling pathway.
15p
vimackenziebezos
30-11-2021
4
1
Download
-
A novel implant for occipitocervical fusion consisting of a median plate with an additional hook inserting in the foramen magnum was tested. Aim of this study was to test the stability of a new implant for occipitocervical fusion against the already available and employed median plate implant without hook.
9p
vianttinic2711
20-04-2021
9
2
Download
-
Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested.
6p
vianttinic2711
20-04-2021
9
2
Download
-
Dynamic interspinous stabilization devices generally provide satisfactory results, but can result in recurrent lumbar disc herniation, spinous process fracture, or bone resorption of the spinous process. The purpose of this study was to investigate if the Wallis dynamic stabilization device is associated with bone resorption.
9p
vianttinic2711
20-04-2021
7
1
Download
-
Treatment of atlantoaxial dislocation is aimed at reduction and stabilization of the atlantoaxial joint. 3D printing refers to a process where additive manufacturing is achieved under precise computer control. Literature on its utilization in anterior atlantoaxial fixation and fusion is rare.
6p
vianttinic2711
20-04-2021
15
2
Download
-
Based on a computer-assisted literature search, this case is the first description of repeated loosening of metallic internal fixation implants after pelvic ring stabilization, associated with intravesical metal migration and micturition with expulsion of two bone screws.
4p
vioregon2711
22-02-2021
8
2
Download
-
Interspinous distraction devices (IDD) are due to maintain or restore intersegmental range of motion (iROM) in a controlled fashion with the aim of stabilization the affected level dynamically. The following study is the first to present clinical and radiological data with the Wallis® spacer during a follow-up of 24 months.
8p
vioregon2711
22-02-2021
16
2
Download
-
Although minimally invasive posterior spine implant systems have been introduced, clinical studies reported on reduced quality of spinal column realignment due to correction loss. The aim of this study was to compare biomechanically two minimally invasive spine stabilization systems versus the Universal Spine Stabilization system (USS).
8p
vioregon2711
22-02-2021
8
2
Download
-
For osteoporotic femoral neck fractures, suitable bone-implant stability is critical for pain relief, early return to daily activities and reduction of complications. Teriparatide (parathyroid hormone [PTH1-34]) can improve bone-implant stability in some basic studies.
9p
vioregon2711
22-02-2021
12
2
Download
-
There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. Mechanically, these four sorts of artificial joint replacement are stabilized in quantity. Cemented short-stem prostheses present the biggest stress, while porous short-stem & cemented long-stem designs are equivalently better than porous long-stem prostheses and alternatives for femoral-head replacement. The preferred design of those two depends on clinical conditions.
12p
vitennessee2711
02-02-2021
7
2
Download
-
The treatment aims of periprosthetic fractures (PPF) of the distal femur are a gentle stabilization, an early load-bearing capacity and a rapid postoperative mobilization of the affected patients. For the therapy planning of PPF a standardized classification is necessary which leads to a clear and safe therapy recommendation.
8p
vitennessee2711
02-02-2021
8
1
Download
-
Although various surgical methods are used to treat lumbosacral tuberculosis, no unified surgical approach exists. Thus, exploring an optimal operation method has substantial clinical importance. Evaluate the initial stability of a new surgical method, a one-stage anterior debridement and cage implantation combined with anterior-lateral fixation by a dual screw-rod construct.
8p
vivermont2711
28-01-2021
12
2
Download
-
The popliteus tendon (PT) or lateral collateral ligament (LCL) stabilizes the postero-lateral aspects of the knees. When surgeons perform total knee arthroplasty (TKA), PT and LCL iatrogenic injuries are a risk because the femoral attachments are relatively close to the femoral bone resection area.
7p
vimariana2711
22-12-2020
6
1
Download
-
Thoracolumbar burst fractures can be treated with posterior short-segment fixation. However, no classification can help to estimate whether the healed vertebral body will have sufficient stability after implant removal. We aimed to develop a Healing Pattern Classification (HPC) to evaluate the stability of the healed vertebra based on cavity size and location.
10p
vimariana2711
22-12-2020
5
0
Download
-
Reconstruction of the Anterior cruciate ligament (ACL) using tendon grafting is an established method for restoring knee function and stability. Multiple methods are established for graft fixation. Several involve anchoring the autograft distant to the joint with hardware that remains implanted.
8p
vimariana2711
22-12-2020
43
1
Download
-
Calcium phosphate (CaP) coating on melt electrowritten (MEW) substrates is a potential candidate for bone regeneration influencing the interaction of osteoblasts with implanted scaffolds. Pretreatment to improve hydrophilicity of the hydrophobic polymer fibres affects subsequent coating with bioactive compounds like CaP.
10p
tamynhan4
06-09-2020
14
1
Download
-
Bone implant materials cause the most common complication of bone infections in orthopedic surgery, resulting in implant failure. Antibiotic treatment of bone infections leads to problems such as bacterial resistance and reduced osteogenic capacity.
12p
trinhthamhodang1
14-11-2019
9
0
Download
-
In 1998, it was first reported that a silica material with large, uniform mesopores arranged into a two-demensional hexagonal structure is synthesized using triblock copolymer and oligomer templates poly (ethylene oxide), (EO)n. This silica was denoted SBA-15. Up to now, it is believed that ordered mesopores of SBA-15 are connected through complementary pores (microporores and small mesopores) in the siliceous pore walls. SBA-15 can be readily synthesized using cheap materials and it shows attractive structural properties, very good hydrothemal stability.
5p
uocvong01
24-09-2015
71
2
Download
-
The rapid mortgage credit growth experienced in recent years in mature and emerging countries has raised some stability concerns. Many European credit institutions in mature markets have reacted by increasing securitization, particularly via mortgage covered bonds. From the issuer’s perspective, these instruments have become an attractive funding source and a tool for assetliability management; from the investor’s perspective, covered bonds enjoy a favorable risk-return profile and a very liquid market.
0p
taisaocothedung
12-01-2013
62
2
Download
CHỦ ĐỀ BẠN MUỐN TÌM
![](images/graphics/blank.gif)